I.3. Data types

I.3.1. user-level: User login level

User login level - commands available are restricted according to assigned level.

Table I.45. user-level: User login level

ValueDescription
NOBODYUnknown or not logged in user
GUESTGuest user
USERNormal unprivileged user
ADMINSystem administrator
DEBUGSystem debugger

I.3.2. ppp-dump: PPP dump format

Table I.46. ppp-dump: PPP dump format

ValueDescription
defaultMixed hex/decode
decodedDecoded only
decoded+rawDecoded + raw
rawRaw hex

I.3.3. autoloadtype: Type of s/w auto load

Table I.47. autoloadtype: Type of s/w auto load

ValueDescription
falseDo no auto load
factoryLoad factory releases
betaLoad beta test releases
alphaLoad test releases

I.3.4. lacp-hot-standby: LACP hot standby mode

Table I.48. lacp-hot-standby: LACP hot standby mode

ValueDescription
enabledNormal hot standby
nosyncDon't set SYNC (helps with some switches)
disabledDon't do hot standby

I.3.5. config-access: Type of access user has to config

Table I.49. config-access: Type of access user has to config

ValueDescription
noneNo access unless explicitly listed
viewView only access (no passwords)
readRead only access (with passwords)
demoFull view and edit access but can only test config, not save
testFull view and edit access but must test save config first
fullFull view and edit access

I.3.6. eap-subsystem: Subsystem with EAP access control

Table I.50. eap-subsystem: Subsystem with EAP access control

ValueDescription
IPsecIPsec/IKEv2 VPN

I.3.7. eap-method: EAP access method

Table I.51. eap-method: EAP access method

ValueDescription
MD5MD5 Challenge
MSChapV2MS Challenge

I.3.8. syslog-severity: Syslog severity

Log severity - different loggable events log at different levels.

Table I.52. syslog-severity: Syslog severity

ValueDescription
EMERGSystem is unstable
ALERTAction must be taken immediately
CRIT Critical conditions
ERRError conditions
WARNINGWarning conditions
NOTICENormal but significant events
INFOInformational
DEBUGDebug level messages
NO-LOGGINGNo logging

I.3.9. syslog-facility: Syslog facility

Syslog facility, usually used to control which log file the syslog is written to.

Table I.53. syslog-facility: Syslog facility

ValueDescription
KERNKernel messages
USERUser level messges
MAILMail system
DAEMONSystem Daemons
AUTHSecurity/auth
SYSLOGInternal to syslogd
LPRPrinter
NEWSNews
UUCPUUCP
CRONCron deamon
AUTHPRIVprivate security/auth
FTPFile transfer
12Unused
13Unused
14Unused
15Unused
LOCAL0Local 0
LOCAL1Local 1
LOCAL2Local 2
LOCAL3Local 3
LOCAL4Local 4
LOCAL5Local 5
LOCAL6Local 6
LOCAL7Local 7

I.3.10. http-mode: HTTP/HTTPS security mode

Table I.54. http-mode: HTTP/HTTPS security mode

ValueDescription
http-onlyNo HTTPS access
http+httpsBoth HTTP and HTTPS access
https-onlyNo HTTP access
redirect-to-httpsHTTP accesses are redirected to use HTTPS
redirect-to-https-if-acmeHTTP accesses are redirected to use HTTPS if ACME set up for hostname
redirect-to-https-except-trustedHTTP accesses are redirected to use HTTPS (except trusted IPs)

I.3.11. month: Month name (3 letter)

Table I.55. month: Month name (3 letter)

ValueDescription
JanJanuary
FebFebruary
MarMarch
AprApril
MayMay
JunJune
JulJuly
AugAugust
SepSeptember
OctOctober
NovNovember
DecDecember

I.3.12. day: Day name (3 letter)

Table I.56. day: Day name (3 letter)

ValueDescription
SunSunday
MonMonday
TueTuesday
WedWednesday
ThuThursday
FriFriday
SatSaturday

I.3.13. port: Physical port

Table I.57. port: Physical port

ValueDescription
0Port 0 (left)
1Port 1 (right)

I.3.14. Crossover: Crossover configuration

Physical port crossover configuration.

Table I.58. Crossover: Crossover configuration

ValueDescription
autoCrossover is determined automatically
MDIForce no crossover

I.3.15. LinkFlow: Physical port flow control setting

Table I.59. LinkFlow: Physical port flow control setting

ValueDescription
noneNo flow control
symmetricCan support two-way flow control
send-pausesCan send pauses but does not support pause reception
anyCan receive pauses and may send pauses if required

I.3.16. LinkClock: Physical port Gigabit clock master/slave setting

Table I.60. LinkClock: Physical port Gigabit clock master/slave setting

ValueDescription
prefer-masterMaster status negotiated; preference for master
prefer-slaveMaster status negotiated; preference for slave
force-masterMaster status forced
force-slaveSlave status forced

I.3.17. LinkLED-y: Yellow LED setting

Table I.61. LinkLED-y: Yellow LED setting

ValueDescription
Link/CollisionOn when link up; blink when collisions detected
ActivityBlink when Tx or Rx activity
FaultOn when autonegotiation mismatch
TxBlink when Tx activity
OffPermanently off
OnPermanently on

I.3.18. LinkLED-g: Green LED setting

Table I.62. LinkLED-g: Green LED setting

ValueDescription
Link/ActivityOn when link up; blink when Tx or Rx activity
CollisionBlink when collisions detected
RxBlink when Rx activity
OffPermanently off
OnPermanently on

I.3.19. LinkPower: PHY power saving options

Table I.63. LinkPower: PHY power saving options

ValueDescription
noneNo power saving
fullFull power saving

I.3.20. LinkFault: Link fault type to send

Table I.64. LinkFault: Link fault type to send

ValueDescription
falseNo fault
trueSend fault
off-lineSend offline fault (1G)
aneSend ANE fault (1G)

I.3.21. sampling-protocol: Sampling protocol

Table I.65. sampling-protocol: Sampling protocol

ValueDescription
sflowUse sFlow protocol
ipfix-psampUse IPFIX/PSAMP protocol
ipfix-legacyUse legacy (Cisco-style) IPFIX

I.3.22. trunk-mode: Trunk port mode

Table I.66. trunk-mode: Trunk port mode

ValueDescription
falseNot trunking
randomRandom trunking
l2-hashL2 hashed trunking
l23-hashL2 and L3 hashed trunking
l3-hashL3 hashed trunking

I.3.23. ramode: IPv6 route announce level

IPv6 route announcement mode and level

Table I.67. ramode: IPv6 route announce level

ValueDescription
falseDo not announce
lowAnnounce as low priority
mediumAnnounce as medium priority
highAnnounce as high priority
trueAnnounce as default (medium) priority
dhcp6triggeredWhen triggered by DHCPv6

I.3.24. sampling-mode: Sampling mode

Table I.68. sampling-mode: Sampling mode

ValueDescription
offDon't perform sampling
ingressSample incoming traffic
egressSample outgoing traffic
bothSample incoming and outgoing traffic

I.3.25. sfoption: Source filter option

Table I.69. sfoption: Source filter option

ValueDescription
falseNo source filter checks
blackholeCheck replies blackholed
nowhereCheck replies valid
selfCheck replies valid and not self
trueCheck replies down same port/vlan