G.8. Monitoring information (deprecated)

General monitoring information. These OIDs are deprecated, please migrate to the new ones in Section G.6.

Table G.16. iso.3.6.1.4.1.24693.1.X.Y

X.YTypeMeaning
1.1Integer (mV)Voltage: "A" power supply. Should be around 12V. May show a few volts when no power connected
1.2Integer (mV)Voltage: "B" power supply. Should be around 12V. May show a few volts when no power connected
1.3Integer (mV)Voltage: Combined 12V supply. Will be slightly lower than highest of "A" and "B" due to diode drop
1.4Integer (mV)Voltage: 3.3V reference
1.5Integer (mV)Voltage: 1.8V reference
1.6Integer (mV)Voltage: 1.2V reference
1.7Integer (mV)Voltage: 1.1V reference
1.8Integer (mV)Voltage: 3.3V fan power, if present
1.9Integer (mV)Voltage: 1.2V fan power, if present
2.1Integer (mC)Temperature: Fan controller
2.2Integer (mC)Temperature: CPU
2.3Integer (mC)Temperature: RTC
3.1Integer (rpm)Speed: Fan 1
3.2Integer (rpm)Speed: Fan 2